Vfp-T Three Phase Variable Frequency AC Power Supply
-
Price:
Negotiable
- minimum:
- Total supply:
-
Delivery term:
The date of payment from buyers deliver within days
-
seat:
Jiangsu
-
Validity to:
Long-term effective
-
Last update:
2017-10-28 05:42
-
Browse the number:
269
+
Yangzhou Idealtek Electronics Co., Ltd.
- Contactaixin:
Mr. Stephen Cao(Mr.)
- Email: telephone:
-
Arrea:
Jiangsu
Address:343, No. 8 Wenchang Middle Road, Guangling District, Yangzhou, Jiangsu, China 225000
- Website:
+
VFP-T Three phase Variable Frequency AC Power Supply
Brief Introduction
The VFP-T series is three-phase output model which has various output range from 3KVA to 600KVA, it has high resolution & stability and full protection functions, output voltage & frequency continuously adjustable and easy operation-panel. It's widely used as a simulated AC input for equipment or home appliance testing.
Features
1. Output voltage & frequency adjustable via potentiometer or key button
2. Output Range:
a. Voltage - Low level: 0~150V, High level: 150~300V or 0~300V continuously adjustable (best simulate input voltage of different countries)
b. Frequency: 45~70Hz (adjustable)
50Hz, 60Hz, 100Hz, 200Hz, 400Hz (fixed)
c. Power: 3VA ~ 600KVA for selection.
3. High output voltage accuracy and output frequency stability
4. Response time: 2ms
5. 0.5% load stability.
6. ±1.5% waveform distortion (resistive load)
7. High-accuracy display for output voltage, current, frequency, power & power factor.
8. Full Protection functions (over voltage, over load, over temp, over current, short-circuit)
9. Friendly Operation Panel.
Applications
1. For electron-products testing, debugging, powering for electro-instrument.
2. Electromotor, electron manufacturing, IT industry, computer, labs and so on.
3. Other situations that need frequency conversion power supply.
General Technical Specification
Output power | 3KVA | 6KVA | 10KVA | 15KVA | 20KVA | 30KVA | 45KVA | 60KVA | 100KVA | 120KVA | 150KVA | 200KVA | 300KVA | 400KVA | 500KVA | 600KVA | |||||||||||
Circuit mode | IGBT/PWM pulsing width modulating mode | ||||||||||||||||||||||||||
AC input | Single-phase 220V/50Hz, 60Hz | Three-phase 380V/50Hz, 60Hz | |||||||||||||||||||||||||
AC output | Phase | Three-phase (phase difference: 120±2°) | |||||||||||||||||||||||||
Voltage | Low level | 0~150V (phase voltage) / 0 ~ 260V (line voltage) | |||||||||||||||||||||||||
High level | 0~300V (phase voltage) / 0 ~ 520V (line voltage) | ||||||||||||||||||||||||||
Frequency | 45~70Hz (adjustable) 50Hz, 60Hz, 100Hz, 200Hz, 400Hz (fixed) |
||||||||||||||||||||||||||
Max. Current | 0V~150V | 8.4A | 16.8A | 28A | 42A | 50A | 84A | 125A | 168A | 276A | 336A | 416A | 556A | 834A | 1112A | 1400A | 1667A | ||||||||||
0V~300V | 4.2A | 8.4A | 14A | 21A | 25A | 42A | 63A | 84A | 138A | 168A | 208A | 278A | 417A | 556A | 700A | 833A | |||||||||||
Frequency Stability | ≤±0.1% | ||||||||||||||||||||||||||
Load Stability | ±0.5% | ||||||||||||||||||||||||||
Waveform distortion | ≤1.5% (resistive load) | ||||||||||||||||||||||||||
Response time | ≤2ms | ||||||||||||||||||||||||||
Display | Voltage, Current, Power, Frequency & Power factor all 4-digit LED display. | ||||||||||||||||||||||||||
Display resolution | Voltage meter: 0.1V Current meter: less than 4A: 0.001A more than 4A: 0.01A Power meter: less than 200W: 0.1W more than 200W: 1W Frequency meter: 0.1Hz Power factor: 0.001 (optional) |
A, B, C three phase parameters switchable LCD display | |||||||||||||||||||||||||
Protection functions | Auto tripping and alarm when over voltage, over load, over temp, over current and short-circuit. (Input & output no fusing breaker) |
||||||||||||||||||||||||||
Cooling system | Forced air-cooling type | ||||||||||||||||||||||||||
Working Temperature Relative humidity |
Temperature: 0°C~45°C Humidity: 0~90% (non-coagulating) |
||||||||||||||||||||||||||
Size (W*D*H) (mm) | 430*650*650 | 610*950*725 | 700*1200*1020 | 700*1340*1280 | 800*1340*1420 | 950*1500*1800 | 850*1200*1020 | 850*1200*1600 | 900*1400*1600 | ||||||||||||||||||
Weight (Kg) | 92 | 125 | 180 | 245 | 360 | 400 | 550 | 650 | `1050 | 1250 | 1350 | 2050 | 3050 | 4050 | 5600 | 6300 | |||||||||||
Custom-made specifications are available.
Products gallery
Storage
Pay attention to the following points during temporary & long-term storage.
1. Store the power supply in our packing box
2. Long-term storage would lead to electrolytic capacitor degradation, it should be powered up yearly, at least 5 hours power-on time, input voltage should be increased to rated value by voltage regulator.
Warranty
1. The warranty period of this product is 12 months, free repair within warranty period except for man‐made damages or irresistible forces.
The following cases during under warranty are not included in free-warranty scope:
(1). Incorrect operation & maintenance of the power source that cause fault.
(2). Natural loss of consumable material (shell, connector etc.)
(3). Manual damage caused by modification or dismantle
(4). Damage caused by external equipments or third-party product or plug-in units.
(5). Force majeure factors, such as fire, flood or input grid abnormal.
(6). Unilateral amendment or modification on our LOGO or part number.
(7). Fault caused by abnormal usage of power source.
(8). Other non-product quality causes
2. Reasonable maintenance & repair costs should be charged after warranty period.
Remark: Price offered in this page is for reference only, price changes would be made without notice
Please contact us for accurate offering, thanks for understanding.
other products